<%@LANGUAGE="VBSCRIPT" CODEPAGE="1252"%> <% Dim rsSwiperSub Dim rsSwiperSub_numRows Set rsSwiperSub = Server.CreateObject("ADODB.Recordset") rsSwiperSub.ActiveConnection = MM_dbase1_STRING rsSwiperSub.Source = "SELECT * FROM QueryProductDetails" rsSwiperSub.CursorType = 0 rsSwiperSub.CursorLocation = 2 rsSwiperSub.LockType = 1 rsSwiperSub.Open() rsSwiperSub_numRows = 0 %> <% Dim rsSwiperMain Dim rsSwiperMain_numRows Set rsSwiperMain = Server.CreateObject("ADODB.Recordset") rsSwiperMain.ActiveConnection = MM_dbase1_STRING rsSwiperMain.Source = "SELECT * FROM QueryDistinctCategory" rsSwiperMain.CursorType = 0 rsSwiperMain.CursorLocation = 2 rsSwiperMain.LockType = 1 rsSwiperMain.Open() rsSwiperMain_numRows = 0 %> <% Dim localTime Dim localTime_numRows Set localTime = Server.CreateObject("ADODB.Recordset") localTime.ActiveConnection = MM_dbase1_STRING localTime.Source = "SELECT * FROM QueryTimeDate" localTime.CursorType = 0 localTime.CursorLocation = 2 localTime.LockType = 1 localTime.Open() localTime_numRows = 0 %> <% Dim productInfo__MMColParam productInfo__MMColParam = "1" If (Request.QueryString("productInfoID") <> "") Then productInfo__MMColParam = Request.QueryString("productInfoID") End If %> <% Dim productInfo Dim productInfo_numRows Set productInfo = Server.CreateObject("ADODB.Recordset") productInfo.ActiveConnection = MM_dbase1_STRING productInfo.Source = "SELECT * FROM QueryProductInfo WHERE productInfoID = " + Replace(productInfo__MMColParam, "'", "''") + "" productInfo.CursorType = 0 productInfo.CursorLocation = 2 productInfo.LockType = 1 productInfo.Open() productInfo_numRows = 0 %> Global Aviation
Global Aviation Support Pty. Ltd
Sunshine Coast Airport, Queensland, Australia
Tel: 07 5448 8877 Fax: 07 5448 8866
Email:
Local Time - <%= DoDateTime((localTime.Fields.Item("Time").Value), 4, 1033) %>, <%= DoDateTime((localTime.Fields.Item("Date").Value), 1, 1033) %>
 

Smart Engine Analyzer Model SR-8A

(STC'd PMA'd)
The SR-8A is an affordable automatic engine analyzer that can monitor up to eight engine temperature parameters. Supplied standard with six foot cables they can be ordered in any length required.
Smart Engine Analyzer Model SR-8A Large Display. 8 Channels. Use only the channels you need and save on probe and cable costs. Measures EGT's, CHT's, TIT, Oil Temp, OAT, Carb. Temp and Other, up to 8 channels. Manual and Automatic Diagnostics (Scan) Modes. Automatically finds the hottest EGT or CHT. Factory set EGT Over-Temp Limits (1650°F). Factory set EGT Under-Temp Limits (1100°F). Factory set CHT Over-Temp Limit (500°F). Differential Limit set from back panel to 95°F or 195°F. Selectable Scan Rate and Number of Channels to be Scanned (6 or 8).

Specifications: 2¼" Mount. 5.35" Depth. 16 oz. Unit. 3.5 oz for each probe and 6' cable, 7 oz for each probe and 20' cable. 1°F Resolution. Accuracy: ½%. Viewable in direct sunlight. Backlit for night operation. Operates from 7.5 to 35 volts at .3 amps.